Forecasting Natural Gas Demand
What weather, home heating, and electricity use tell us about future gas use.
1. Introduction
Gas demand means the amount of natural gas people and businesses use. Cold weather increases the need for heating. Hot weather increases the need for electricity to run air conditioning. How much extra gas is needed depends on the heating fuels and power plants in each place.
I tested whether three changes could make monthly gas-use forecasts more accurate: giving states different importance in the weather average, making forecasts for individual states, and predicting electricity production before predicting gas use. I also compared my forecasts with saved forecasts from the U.S. Energy Information Administration (EIA) and explored whether electricity sales could help identify data-center demand.
I study four groups of gas users (sectors):
- Residential: homes that use gas for heating, hot water, cooking, and other household needs.
- Commercial: buildings such as offices, shops, schools, and hospitals.
- Industrial: factories and other industrial users.
- Electric power: power plants that burn gas to make electricity.
The four-sector total is the sum of these uses. It leaves out gas used in pipelines, at gas wells and processing plants, and in vehicles. It therefore does not represent every use of natural gas in the country.
2. Data
How gas use is measured
The main study covers the 48 connected U.S. states and excludes Washington, DC. I divide each month’s gas volume by its number of days. The result is billion cubic feet per day (Bcf/day), a daily rate that lets a short month and a long month be compared fairly.
Where every state reports a value, I add the states together. Some industrial values are withheld. In those cases, I use EIA’s published U.S. total and subtract Alaska, Hawaii, and DC. Where both methods can be checked, their totals differ by at most 7 million cubic feet.
A missing value stays missing. I enter zero only when the official table marks a value as “Not Applicable.”
The electricity data cover utility power plants and independent power producers. They include plants that make both electricity and useful heat, called combined heat and power plants. They exclude generators counted in the commercial and industrial sectors and small-scale solar. I check the electricity totals against regional records. Electricity sales measure what customers buy, but that electricity may have been produced in another state.
Measuring weather and deciding which states matter most
The National Oceanic and Atmospheric Administration (NOAA) provides degree-day data. Degree days summarize heating and cooling needs using 65°F as a reference. A heating degree day counts how far a day’s average temperature is below that reference. A cooling degree day counts how far it is above. Larger totals mean more need for heating or cooling.
A national weather average needs rules for how much each state contributes to the average, which we can represent using weights. Population weights give more importance to states with more people. Gas-heated-home weights give more importance to states with more homes heated by utility gas. The second rule may better reflect where cold weather will raise gas use.
NOAA already uses 2010 population to combine weather observations within each state. I change only how states are combined with one another. There is one small mismatch: Maryland’s weather area includes DC, but my gas-use total excludes DC.
I take annual population and gas-heated-home counts from the Census Bureau’s American Community Survey (ACS). Gas-heated homes here means occupied homes heated with utility gas delivered through pipelines. It excludes bottled and tank gas, including liquefied petroleum (LP) gas such as propane. The series begins in 2006. Standard 2020 estimates were not released, so I carry the latest available estimate forward.
I also try EIA’s counts of gas customers. A customer account is not necessarily a building, and a change of supplier can cause double counting. Home-heating counts are an imperfect measure for business heating too. They are a stand-in, rather than a direct count of gas-heated commercial buildings.
What information a forecast is allowed to use
Each forecast is dated the first day of the month it predicts. To allow for reporting delays, I use gas and electricity observations at least three months old and Henry Hub prices at least two months old. Annual state weights become available in the model no earlier than January two years after the year they describe.
For weather, the forecast uses the average of the previous 20 occurrences of that calendar month. Model fitting begins with January 2008. I score the forecasts on all 96 months from 2018 through 2025.
The historical data include revisions made after their first release. My delay rules reduce the risk of using information too early, but they cannot recreate exactly what a forecaster knew at every past date.
3. Models
The simple forecast and the fitted models
The benchmark is the previous year’s gas use per day for the same calendar month. It already captures much of the winter heating and summer cooling pattern. The charts call it seasonal naive.
The main national model uses earlier gas use, recent growth, the month of the year, longer-term trends, Henry Hub prices, and heating and cooling degree days. Its power-sector version also uses earlier electricity growth and the shares of generation supplied by gas, coal, and renewables.
This model is ridge regression. For home and business demand, I use gas-heated-home weather weights. For industrial demand, I use population weights. For power demand, I use each state’s electricity production in the same month of the previous year.
The state model, labeled “State panel” in the charts, keeps some common patterns but lets states have different demand levels and weather responses. I add the 48 state forecasts within each sector to get that sector’s total. I also test gradient boosting. I recorded the settings before running the full historical test and did not tune them on the evaluation years.
Predicting power-plant gas use in two steps
The direct model predicts power plants’ gas use in one step. The two-stage model first predicts how much electricity will be generated and what share will come from gas. It then uses the previous 12 available months to estimate how much gas is needed for each unit of gas-generated electricity.
The model limits the share and the conversion rate to avoid unrealistic estimates. This approach follows a physical link between electricity and fuel use, but a mistake at either stage can affect the final answer. Fuel costs, outages, hydroelectricity, renewables, and electricity transfers between states also influence which plants run.
How I check whether a model helps
I refit the models each month using earlier observations, including the weather already known for those earlier months. The main forecasts use normal weather for the month being forecast. A separate check gives the model the weather that actually happened. The saved results contain 3,744 predictions for the 48-state sector totals and 36,864 state predictions.
Mean absolute error (MAE) is the average size of a forecast miss, ignoring whether the forecast was too high or too low. Here it is measured in Bcf/day. The download also includes root mean square error (RMSE), which gives more weight to large misses, along with results for individual years, seasons, and states.
I planned nine main comparisons of weather weights, state models, and the two-stage power model. A smaller average error alone is not enough to call a change reliable. I also check how much the estimated improvement could vary if a different set of months had been observed.
To estimate that uncertainty, I resample matched forecast errors in 12-month blocks. This keeps groups of neighboring months together, because their errors can be related. The resulting 95% interval shows uncertainty about the average improvement. If it includes zero, both an improvement and no improvement remain consistent with that calculation.
The tests also account for related errors across time and for trying nine comparisons. The adjustment is called the Holm method. Its adjusted p-value is a test score, where a smaller value gives stronger evidence against equal forecast accuracy, under the test’s assumptions. I count a gain as supported only when the average gain is positive, the whole interval is above zero, and the adjusted p-value is below 0.05. These rules reduce the chance of treating a lucky result as a useful improvement.
I also change the training window and ridge penalty to see how sensitive the answers are to those choices.
A prediction band is a range around a forecast, rather than a single guess. I build it from at least 24 earlier forecast errors whose true outcomes would already have been reported. The total-demand band uses errors for the combined total, because errors in different sectors can move together. Coverage is the percentage of later observations that fall inside the band. I report it instead of assuming the band works as intended.
4. Results
The national model improves on repeating last year
| Sector | Last-year MAE | National-model MAE | State-model MAE | Boosting MAE | National improvement |
|---|---|---|---|---|---|
| Residential | 1.58 | 1.29 | 1.41 | 1.16 | +18.4% |
| Commercial | 0.81 | 0.70 | 0.77 | 0.63 | +13.9% |
| Industrial | 0.60 | 0.49 | 0.49 | 0.67 | +18.8% |
| Electric power | 2.11 | 1.58 | 2.00 | 2.61 | +24.9% |
Compared with the same-month-last-year benchmark, the main national model lowers MAE by 18.4% for homes, 13.9% for businesses, 18.8% for industry, and 24.9% for power plants. A positive gain means a smaller average miss. These comparisons describe how much the national model improves on a simple starting point. The nine planned tests below ask which specific model changes help.
Giving more importance to gas-heated homes helps
Switching from population weights to gas-heated-home weights lowers home-use MAE by 5.6% and business-use MAE by 5.0%. Using gas-customer counts also helps both sectors. All four weighting comparisons pass the three checks described above. This clearest result is that weather averages should pay attention to where gas is actually used for heating.
The result does not mean the weather measures are completely different. They share much of the same seasonal pattern. The test is whether the smaller differences between them improve the forecasts.
In the table, H1 labels the weather-weight comparisons, H2 labels the state-model comparisons, and H3 labels the two-stage power comparison.
| Comparison | Average-error reduction | 95% interval | Adjusted p-value | Passes all checks? |
|---|---|---|---|---|
| H1 · Residential · Gas-heated homes | +5.6% | +4.2% to +6.9% | <0.001 | Yes |
| H1 · Residential · Gas customers | +4.6% | +3.2% to +5.8% | <0.001 | Yes |
| H1 · Commercial · Gas-heated homes | +5.0% | +4.2% to +5.9% | <0.001 | Yes |
| H1 · Commercial · Gas customers | +4.7% | +3.8% to +5.8% | <0.001 | Yes |
| H2 · Residential · State panel | -9.0% | -14.3% to -5.7% | <0.001 | No |
| H2 · Commercial · State panel | -9.7% | -15.5% to -6.3% | <0.001 | No |
| H2 · Industrial · State panel | -0.2% | -15.2% to +14.8% | 0.986 | No |
| H2 · Electric power · State panel | -26.8% | -56.2% to +1.9% | 0.130 | No |
| H3 · Electric power · Two-stage power | +8.8% | +0.7% to +16.7% | 0.130 | No |
Of the nine planned comparisons, 4 pass all three checks for the forecasts. The separate exercise that already knows the weather also has 4 supported gains. The table includes every planned comparison, including changes that raise errors and changes whose gains remain uncertain.
Giving the model the weather that actually occurred lowers MAE by 42.6% for homes and 5.5% for power plants.
Separate state forecasts do not improve the total
The tested state model does not lower combined-demand MAE in any of the four sectors. State detail adds more effects to estimate, while some states have smaller or withheld samples. More detail therefore does not automatically mean a better forecast. This finding applies to this particular state model, not every possible use of state data.
The electricity-first approach needs more testing
The two-stage model has an MAE of 1.44 Bcf/day. Its average error is 8.8% lower than the direct power model’s. However, it does not pass all three checks. Its Holm-adjusted p-value is 0.130, above the 0.05 cutoff, even though the resampling interval is entirely positive. I therefore treat the apparent improvement as promising but unproven. The seasonal table shows where that average gain comes from. “Shoulder” means April, May, and October, between the defined summer and winter groups.
| Season | Months | Direct-model MAE | Two-stage MAE |
|---|---|---|---|
| Shoulder | 24 | 1.41 | 1.28 |
| Summer (Jun-Sep) | 32 | 2.02 | 1.60 |
| Winter (Nov-Mar) | 40 | 1.33 | 1.41 |
How the forecasts compare with EIA’s outlook
| Sector | Repeat last year | Research: month start | Research: earlier inputs | Saved EIA outlook |
|---|---|---|---|---|
| Residential | 1.59 | 1.29 | 1.22 | 1.18 |
| Commercial | 0.82 | 0.70 | 0.66 | 0.69 |
| Industrial | 0.61 | 0.50 | 0.54 | 0.74 |
| Electric power | 2.10 | 1.58 | 1.71 | 1.90 |
EIA publishes the Short-Term Energy Outlook (STEO), which includes gas-demand forecasts. Its archived forecasts have lower MAE than my earlier-input model in 1 of the four sectors. I use the preceding month’s issue from the official EIA archive.
I also move my model’s information cutoff earlier to make this a closer comparison. That version uses gas and electricity data at least four months old, prices at least three months old, and the annual weights available one month earlier. I add seasonal estimates for Alaska, Hawaii, and DC to match EIA’s full-U.S. target.
This is still an imperfect comparison. My historical inputs contain later revisions, while EIA has a wider set of information and its own weather assumptions.
Do the results hold across years and model choices?
| Sector | Train from 2011 | Rolling 8 years | Weaker penalty | Stronger penalty |
|---|---|---|---|---|
| Residential | +2.5% | +5.3% | +2.4% | -8.9% |
| Commercial | +3.8% | +4.4% | -0.9% | -3.0% |
| Industrial | -2.7% | +2.8% | -2.3% | -5.4% |
| Electric power | -6.9% | -2.1% | +1.1% | -8.9% |
The alternative training windows and penalties show how much the scores change when the fitting choices change. Starting in 2011 also avoids much of the period affected by EIA’s 2010 estimation change. “Rolling 8 years” means using only the most recent eight years of training observations. These are checks on the result, not a search for the winning setting.
The dots compare unexpected weather with forecast misses. They use weather measured after the forecast date, so they help explain mistakes. A useful next test would use weather outlooks that were actually available when each gas forecast was made.
| Forecast | Months | Outcomes inside range | Average range width |
|---|---|---|---|
| Commercial | 70 | 82.9% | 2.47 Bcf/day |
| Electric power | 70 | 80.0% | 5.59 Bcf/day |
| Industrial | 70 | 77.1% | 1.70 Bcf/day |
| Residential | 70 | 82.9% | 4.75 Bcf/day |
| Four-sector total | 70 | 85.7% | 10.88 Bcf/day |
The band is intended to cover 80% of future outcomes. In this test it contains 85.7% of the 70 eligible four-sector totals. The bands start only when enough earlier errors are available. Demand patterns can change, so this measured coverage is more useful than assuming that an “80% band” will always cover 80% of later observations.
The data-center test does not isolate data-center gas use
The report from the U.S. Department of Energy and Berkeley Lab, published June 18, 2026, estimates that data centers used 192 terawatt-hours (TWh) of electricity in 2024, or 4.7% of U.S. use. TWh is a unit for an amount of electricity used over time. The report’s 2030 reference scenario is 649 TWh, within a 521–843 TWh range.
I look at five states—Virginia, Texas, Georgia, Ohio, and Arizona—as a possible place to see data-center effects. For their combined power-sector gas use, the model predicts too much in every year from 2020 through 2025. That does not show that data-center demand failed to grow. The model’s trend and earlier demand already capture some growth.
This is a historical grouping of states, and I do not have direct measurements of their data-center electricity use. Power also moves across state lines. These limits mean the forecast misses cannot tell me how much gas demand data centers caused.
I then try growth in commercial electricity sales as a proxy, or stand-in measurement, for changing data-center activity. It does not improve forecasts. Its relative MAE reduction is -1.3%, with a 95% interval of -5.6% to +1.0%. A negative reduction means the error got larger.
Weather cases for November 2026
| Sector / total | Normal weather | 80% forecast range | Mild-weather case | Cold / hot case |
|---|---|---|---|---|
| Residential | 15.83 | 13.56–18.10 | 14.43 | 17.78 |
| Commercial | 11.27 | 10.11–12.43 | 10.61 | 12.20 |
| Industrial | 24.98 | 24.12–25.84 | 24.78 | 25.23 |
| Electric power | 34.06 | 31.28–36.83 | 34.13 | 34.08 |
| Four-sector total | 86.13 | 80.86–91.40 | 83.96 | 89.29 |
This outlook uses gas and electricity observations through August 2026. The normal-weather case averages the previous 20 observations for the same calendar month. The mild and cold/hot cases reuse the full pattern of state weather from 2015 and 2019. I rank the earlier years by heating need in colder months or cooling need in warmer months. The chosen years are near the 10th and 90th percentiles.
5. Conclusion
The clearest lesson is to match the weather average to the way gas is used. Giving more importance to gas-heated homes lowers home and business forecast errors by 5.6% and 5.0% compared with population weights.
- Useful change: gas-heated-home and gas-customer weights improve heating-demand forecasts. These four comparisons account for the 4 supported gains among the nine main forecast tests.
- Change that did not help: adding up separate state forecasts does not beat the national model in any sector in this test.
- Promising, but not established: predicting electricity first gives an average 8.8% improvement for power-sector gas demand, but the evidence does not pass the study’s combined checks.
- Question still unanswered: commercial electricity sales do not improve this forecast or identify the amount of gas demand caused by data centers.
I would next test archived weather forecasts, recreate the original data releases more closely, find better measures of gas heating in commercial buildings, and connect measured data-center electricity use to the places that generate the power.